Abstract:“Unsafe condition” is determined with four-element evaluation criteria, and the problem of flammability exposure time is settled with MonteCarlo method. When determining the service intervals, FTA,FMEA are used to develop safety assessment and find fault modes relating to “unsafe condition”, then calculation of reliability degree distribution and service intervals is achieved.